Module Trans-X TRX inductive TRX12-210, 2-channels, with frontplate 10TE
added to cart
Display basket
302341
Dimensions
Basic print: 100 mm x 160 mm10TE wide: 2-4 circuits of antenna
Material and weight
weight: 0.353kgApplicable standards
EN 50121-3-2:2006EN 50121-4:2006
IEC 61000-6-2:2005
IEC 61000-6-3 / -4:2006
IEC 62236-3-2:2008
IEC 62236-4:2008
Function
The transmission from the vehicle to the fix station and vice versa takes place by running over inductive ground loops or contact wire antennas. It allows the user to operate existing systems miscellaneous with single frequencies in the AF-band and digital transmission through Trans-X.Specification
Current consumption: at 24 V DC:as receiver: ca. 10 W, as sender ca. 10 WInterfaces: Backplane: RS232, RS485, CAN, IBIS Wagenbus (Slave)
Ambient temperature service: -20° C up to +60° C
Ambient temperature store: -40° C up to +40° C
Interfaces: Front: RS232, USB, Ethernet
Inputs: 10 digital inputs, 3 Relais, 3 opto coupler
Power supply: 9 V - 60 V DC
Comments
- RTC (Real Time Clock), environmental sensor, SD-Card-Slot- not security-relevant