Section insulator TW 3000 V bridging for 1 grooved contact wire, suspension for TW

B1146-01

Section insulator TW 3000 V bridging for 1 grooved contact wire, suspension for TW

Dimensions

length: 992 mm
width: 248 mm
height: 100 mm
length between the contact line: 453 mm
length of suspension above eyes: 615 mm
width of suspension above eyes: 115 mm

Material and weight

material: INOX / GFK / PA / BZ / ST tzn
weight: 10.4 kg

Loads

service load: 15 kN
breaking load: 38 kN

Applicable standards

EN 60383-1: 1996
EN 61109: 2006
EN 50119: 2009/A1: 2013

Function

For the electrical separation of adjacent contact line sections.

Specification

contact-wire cross-section: max. 150 mm2
kerf width: 5.6 - 6.9 mm
creepage distances: 215 mm
speed: 80 km/h
operating voltage: 3000 V DC
shortcircuit current: 6000 A
arcing horn distance: 60 mm

Comments

The section insulator can be used on both sides. We recommend driving in the direction of the opening runners. 

For grooved contact wires with cross-section 100-150mm2
AC design as per EN 50149, groove notch width 5.6mm
BF design as per EN 50149, groove notch width 6.92mm