Section insulator ETB 750 V DC with diode negative terminal
added to cart
Display basket
B1312-02
Dimensions
length: 880 mmwidth: 165 mm
height: 231 mm
length between the contact line: 595 mm
width of suspension above eyes: 116 mm
length of suspension above eyes: 600 mm
Material and weight
material: INOX / GFK / PA / BZ / ST tznweight: 12.5 kg
Loads
service load: 20 kNbreaking load: 50 kN
Applicable standards
EN 60383-1: 1996EN 50124-1: 2001/A2: 2005
EN 50119: 2009/A1: 2013
Function
For the electrical separation of adjacent contact line sections. Thanks to the neutral section, and taking into account the max. width of the pantograph head, the two sectors are never connected. Traction current is supplied from the substation with higher feeding voltage via opposing diodes, but also in the vicinity of the neutral section.Specification
contact-wire cross-section: 100 - 120mm2kerf width: 5.6 mm
creepage distances: 470 mm
arcing horn distance: 15 mm
speed: 90 km/h
operating voltage: 750 V DC
Comments
For 1 grooved contact wire 100 -120mm2Design AC according to DIN EN 50149, grove width 5.6mm
Design BF upon request