MIDDLE PART KUSEC 15 kV AC
added to cart
Display basket
B1598-01
Dimensions
Height: 224 mm
Length: 2558 mm
Width: 184 mm
Packaging: 2600 x 620 x 370 mm
Material and weight
Weight: 18 kg
Material: INOX / CuNi2Si / fibreglass reinforced plastic (FRP) / CuMg0.5 / SI / ST (hot-dip galvanised steel)
Loads
Recommended service load: 10 - 18 kN
Breaking load: Min. 55 kN
Applicable standards
EN 50119, IEC 60913
Function
Replacement piece for revision of section insulator KUSEC 25kV AC.
Specification
Short-circuit current: 40000 A
Creepage distance: 830 mm
Arcing horn distance: 140 mm
Operating voltage: 15 kV AC