- Railway
- Tramway
- Cantilever
- Cross-spans
- Catenary
- Crossings
- Tensioning systems
- Disconnectors / Feeds
- Section insulators
- Control units / Electronics
- Soffits / Underpasses
- De-icing system
- Trolleybus
- Cantilever
- Cross-spans
- Crossings
- Switches
- Disconnectors / Feeds
- Section insulators
- Current collector positioning systems
- Bus Equipment
- Control units / Electronics
- Soffits / Underpasses
Section insulator ETB 1200 V non-bridging for 1 grooved contact wire, 102 mm² center piece insulated
added to cart
Display basket
B0786-05
Dimensions
length: 819 mmwidth: 190 mm
height: 87 mm
length of suspension above eyes: 589 mm
width of suspension above eyes: 116 mm
length between the contact line: 589 mm
Material and weight
material: INOX / GFK / PA / BZ / ST tznweight: 6.3 kg
Loads
service load: 15 kNbreaking load: 39.6 kN
Applicable standards
EN 60383-1: 1996
DIN EN 61109: 2006
EN 50119: 2009/A1: 2013
Function
For the electrical separation of adjacent contact line sections.Specification
operating voltage: 1200 V DCkerf width: 5.6 mm
creepage distances: 375 mm
arcing horn distance: 369 mm
contact-wire cross-section: 102 mm2