- Railway
- Tramway
- Cantilever
- Cross-spans
- Catenary
- Crossings
- Tensioning systems
- Disconnectors / Feeds
- Section insulators
- Control units / Electronics
- Soffits / Underpasses
- De-icing system
- Trolleybus
- Cantilever
- Cross-spans
- Crossings
- Switches
- Disconnectors / Feeds
- Section insulators
- Current collector positioning systems
- Bus Equipment
- Control units / Electronics
- Soffits / Underpasses
KUCO 200 Double articulated current collector for trolley poles with Ø38 mm connection
B1526-01
Dimensions
Length: 435 mm
Width: 50 mm
Height: 344 mm
Material and weight
Weight: 2.8 kg
Applicable standards
DIN CLC/TS: 50502
VDE : 0115-502:2009-08
Specification
Allowable ambient temperature: -20 °C to +40 °C
Maximum allowable temperature: ≤ 100 °C
Operational angle horizontal: in service ± 45°, mechanical 360°
Operational angle vertical (angle of the pole): in service 5° to 45°, technical 2° to 48°
Maximum contact pressure: 120 N
Release force for foldaway mechanism: approx. 500 N
Pole diameter: 25 mm 0 / - 0.5
Jumper (copper cable): 35 mm²
Maximum continuous current: 200 A (limited by the jumper)
Maximum peak current: 700 A
Comments
- We recommend the installation on bended trolley poles.
- The compatibility with the overhead contact system in combination with the respective vehicles has to be checked by the user.
- Current collectors are delivered without carbon insert. Carbon inserts can be ordered separately as an option or for test purposes.